Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

standard of measuring water watertube boiler

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :standard of measuring water watertube boiler
  • Supply Capacity : 10 units/month :standard of measuring water watertube boiler
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Hydronic Boiler Comparison: Fire-Tube Boilers vs. Water

    Mar 10, 2021 · In a hydronic system, both fire-tube and water-tube boilers can be viable solutions. A water-tube boiler can be a good selection on a retrofit job with limited space for a large boiler. A primary secondary setup is easy to integrate with an existing system. A fire-tube can also be a good solution for a system with only one set of variable speed Get Price

  • Water Handbook - Boiler Blowdown Control | SUEZ

    The specific conductance of boiler water pro-vides an indirect measure of dissolved solids and can usually be used for blowdown control. However, establishing the rate of blowdown on the basis of the relative specific conductance of feedwater and boiler water does not give a direct measure of the feedwater concentrations within the boiler.Get Price

  • Boiler Blowdown - Engineering ToolBox

    Chemical treatments and continuous surface blowdowns are commonly used to eliminate solids at the same rate as they are added from the feed water. Recommended maximum TDS levels depends on the type of boiler - normally ranging 2000 - 10000 ppm. TDS can be monitored by measuring the electrical conductivity of the boiler water.Get Price

  • Boiler Water Conductivity Measurement Fundamentals

    Boiler Water Conductivity Measurement Fundamentals Get Price

  • Boiler Inspection

    The regulation is similar to the one for the boiler. With the above explanation, your inspection and test plan (ITP) for the water tube boiler needs to meet the requirements of ASME Code Section I. The water tube boiler is made from several components such as the HP Drum, finned Tubes, Headers, Tube Bundle, Stack, Damper, Silencer, Deaerator, etc.Get Price

  • Watertube Boilers - Victory Energy

    O-TYPE WATERTUBE. VOYAGER Series O-type watertube boilers provide a rapid ramp rate. They're easy to ship, install, operate and maintain. Engineered and manufactured to be versatile and reliable. • Up to 500,000+ PPH • Pressures range up to 2,000 PSIG • Temperatures up to 1,050˚F • Saturated or superheated steamGet Price

  • Recommended ABMA & ASME Boiler Water Limits Boiler …

    eventually scale, which deposits on the internal surfaces of the boiler. The result: a serious loss of boiler efficiency, and possibly boiler failure. Scale is a buildup of solid material formed on internal boiler surfaces when the concentration of impurities in the boiler water exceeds their solubility limit and precipitation occurs.Get Price

  • Water-Tube Package Boilers - Process Controls

    B&W's water-tube package boiler (FM) continues this tradition of excellence with more than 4,200 units in operation. Our established reputation for reliability and proven performance is continually enhanced by incorporating the latest technological advancements into our design. B&W is dedicated to providing its water-tube package boilers to a Get Price

  • Volume 2, Water Boilers - Steam, Heating Hot Water, and

    the design of new hot water boiler (boiler), hot water boiler replacement, and modification of existing hot water boiler(s), in all climates. 1.1.2 The requirements of this manual shall apply to all boilers whether they are centralized or decentralized systems.Get Price

  • Failure analysis of the wall tubes of a water-tube boiler

    Sep 01, 2017 · The case under study in this paper corresponds to the history of failure of the evaporator tubes of a water-tube boiler, part of a coal-fired thermoelectric power plant, analyzed from 2001 to 2006 (see Fig. 1).The boiler fed a turbine of 165 MW with steam at a temperature of 500 °C and a pressure of 150 bars (15 MPa), and it had a capacity of 486,000 kg/h.Get Price

  • DIN EN 12952-1 - Water-tube boilers and auxiliary

    Feb 01, 2016 · scope: General. This European Standard applies to water-tube boilers with volumes in excess of two litres for the generation of steam and/or hot water at a maximum allowable pressure PS greater than 0,5 bar and with a temperature in excess of 110 °C as well as auxiliary installations (other plant equipment).Get Price

  • Water Tube Boilers - Energy Solutions Center

    Water tube boilers represent one of a number of pressurized equipment options used to convert water into steam under controlled conditions. Water passes through boiler tubes while the combustion gases remain on the shell side, passing over the tube surfaces.Get Price

  • Environmental Assessment of a Watertube Boiler Firing a

    ----- EPJA-600/Kefid4a February 1986 ENVIRONMENTAL ASSESSMENT OF A WATERTUBE BOILER FIRING A COAL-WATER SLURRY Volume I Technical Results By R. DeRosier and L R. Waterland Acurex Corporation Energy & Environmental Division 555 Clyde Avenue P.O. Box 7555 Mountain View, California 94039 EPA Contract No. Kefid88 EPA Project Officer: R. E Hall Air …Get Price

  • Characteristics of boiler feedwater - Lenntech

    Feed-water purity requirements therefore can vary widely. A low-pressure fire-tube boiler can usually tolerate high feed-water hardness with proper treatment while virtually all impurities must be removed from water used in some modern, high-pressure boilers. Only relatively wide ranges can be given as to maximum levels of alkalis, salt, silica Get Price

  • ASME Boiler Water Guidelines - Waterra Corporation

    Boiler feed water ASME Guidelines for Water Quality in Modern Industrial Water Tube Boilers for Reliable Continuous Operation Boiler Water. Created DateGet Price

  • Firetube vs. Watertube Comparison - Johnston Boiler

    Boiler Water Conductivity Measurement Fundamentals Get Price

  • CHAPTER TWO: Boiler Operation Maintenance & Safety Study …

    2.1.3 Water-tube boilers: • Water-tube boilers have water running through the tubes and fire or gases of combustion surrounding the tubes. The water tubes are connected into a steam drum at the top and a mud drum at the bottom. The fire is in …Get Price

  • Primary Secondary Piping and Water Tube Boiler Cycling | R

    Nov 02, 2020 · Primary – Secondary Piping and Water Tube Boiler Cycling. Primary – Secondary piping is recommended with most water tube condensing boilers. Once the boilers have turned down to the lowest firing rate, cycling will occur. Today the R. L. Deppmann Monday Morning Minutes will look at the bridge piping and the cause of the cycling.Get Price

  • Boiler Water Conductivity Measurement Fundamentals

    Feb 24, 2016 · A probe used to measure the conductivity of a liquid has a 'cell constant'. The value of this constant depends on the physical layout of the probe and the electrical path through the liquid. σT = 20,900 µS/cm. σ25 = Conductivity at 25 °C (µS / cm) Where: Conductivity measurement in the boiler. TDS = 3,500 ppm.Get Price

  • ASME Boiler Water Guidelines - Waterra Corporation

    Firetube vs. Watertube Comparison - Johnston BoilerGet Price

  • Boiler Water Wall Tube Inspection - PowerTech Review

    Jun 02, 2020 · On Jun 2, 2020. For thermal power plants, boiler have always been the heart. Breakdown or an unplanned shut down of a boiler leads to tremendous monetary loss to the asset owners. To be specific water wall tubes act as veins of boiler operation and thus remain the most critical segment as the operational temperature ranges between 500 to 550 Get Price

  • Boiler – Fundamentals and Best Practices

    Steam Production When heat is added to water, its temperature rises at a rate of 0.56°C (1°F) for each heat input of 2.095 kJ/kg (1 Btu/lb) If we take water at 0°C (32°F) and weGet Price

  • Boiler Feed Water and Boiler Water - EWT Water Technology

    Feb 24, 2016 · A probe used to measure the conductivity of a liquid has a 'cell constant'. The value of this constant depends on the physical layout of the probe and the electrical path through the liquid. σT = 20,900 µS/cm. σ25 = Conductivity at 25 °C (µS / cm) Where: Conductivity measurement in the boiler. TDS = 3,500 ppm.Get Price

  • Hydronic Boiler Comparison: Fire-tube Boilers vs. Water

    Aug 12, 2020 · Hydronic Boiler Comparison: Fire-tube Boilers vs. Water-tube Boilers. A Look at Efficiency and Fire-tube Boiler Minimum Flow Rates. With the constant rise in equipment costs, building owners and engineers are constantly looking for ways to decrease initial and utility costs for their HVAC projects. This has driven the market standard to pumps Get Price

  • Boiler Water Conductivity Measurement Fundamentals

    Feb 24, 2016 · A probe used to measure the conductivity of a liquid has a 'cell constant'. The value of this constant depends on the physical layout of the probe and the electrical path through the liquid. σT = 20,900 µS/cm. σ25 = Conductivity …Get Price

  • Water Handbook - Measurement of Steam Purity | SUEZ

    Another commonly used method for measuring steam purity is the sodium tracer technique. This technique is based on the fact that the ratio of total solids to sodium in the steam is the same as the ratio of total solids to sodium in the boiler water for all but the highest-pressure (greater than 2400 psig) boiler systems.Get Price

  • Hydronic Boiler Comparison: Fire-tube Boilers vs. Water

    Aug 12, 2020 · Hydronic Boiler Comparison: Fire-tube Boilers vs. Water-tube Boilers. A Look at Efficiency and Fire-tube Boiler Minimum Flow Rates. With the constant rise in equipment costs, building owners and engineers are constantly looking for ways to decrease initial and utility costs for their HVAC projects. This has driven the market standard to pumps Get Price

  • Hydronic Boiler Comparison: Fire-tube Boilers vs. Water

    Aug 12, 2020 · Hydronic Boiler Comparison: Fire-tube Boilers vs. Water-tube Boilers. A Look at Efficiency and Fire-tube Boiler Minimum Flow Rates. With the constant rise in equipment costs, building owners and engineers are constantly looking for ways to decrease initial and utility costs for their HVAC projects. This has driven the market standard to pumps Get Price

  • Boiler Water Conductivity Measurement Fundamentals

    Feb 24, 2016 · A probe used to measure the conductivity of a liquid has a 'cell constant'. The value of this constant depends on the physical layout of the probe and the electrical path through the liquid. σT = 20,900 µS/cm. σ25 = Conductivity …Get Price

  • (PDF) VGB-Standard Feed Water, Boiler Water and Steam

    This VGB-Standard supports the operator of water-steam cycles in power plants and related branches in selecting and judging suitable water regimes with respect to a safe and economically sound operation of the power plant for a long period of time.Get Price

Discount
7X24 Online