Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
Normal operating pressure for Burnham gas boiler
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Boiler Gauges, how to read the temperature & pressure Get Price
Feb 16, 2002 · Author: jimk-nj (NJ) Hello all, I have a 130k BTU boiler that heats a closed system (not steam) radiator system. When the boiler is cool, the pressure gauge reads 15 PSI - after the boiler runs for 20-30 minutes - the pressure rises up to 19-20 PSI - Is this normal? I understand that water expands when heated, and the job of the expansion tank Get Price
Nov 09, 2012 · Cast iron durability and Burnham quality craftsmanship make the Series 2 residential gas boiler ideal for the replacement and new construction markets. The Series 2 line combines traditional atmospheric draft design with proven boiler controls to ensure reliable, trouble-free operation. Step Opening Gas Valve. Stainless Steel Burners.Get Price
elevated operating temperatures and/or pressures. • This boiler is suitable for installation on combustible flooring. Do not install boiler on carpeting. • Do not tamper with or alter the boiler or controls. • Inspect flueways at least once a year - preferably …Get Price
Boiler Gauges, how to read the temperature & pressure Get Price
Jul 03, 2017 · So e.g. if your pressure vessel is fed by a pump which has say a normal operating pressure of 5 bar, but on no flow the inlet pressure to the pump increases and then the no flow differential pressure increases and so the max pressure from the pump is 10 bar.Get Price
Mar 04, 2021 · Provided the correct gas rate (3.15 cubic metres per hour), a minimum working pressure at maximum output at the gas valve inlet of 16.5 milli-Bar (mB), a static difference of no more than 1mB, and a dynamic difference of no more than 2.5mB can be achieved then the gas pipe sizing would be accepted by Worcester Bosch.Get Price
Burnham boilers malfunctions can be eliminated in a number of cases on your own. Therefore, refer to Burnham boiler troubleshooting chart to learn more about this. Heat Request occurs and start of operating sequence is halted due to an open limit. • Jumper for Low Gas Pressure Switch or device connected to it open.Get Price
GAS-FIRED HOT WATER BOILER How to Determine Your Savings Quality home heating you can count on If you're investigating a heating system for your new home, or if you're replacing an old, ineffi- cient, or worn-out boiler, a Burnhanp Series 2 gas-fired hot water boiler is the home heating investment that' s right for you. Burnham's Series 2 boilerGet Price
• No gas pressure. • Gas pressure under minimum value shown on rating plate. • Gas line not completely purged of air. • Defective Electrode. • Loose burner ground connection. • Defective Ignition Cable. • Defective gas valve (check for 24 Vac at harness during trial for ignition before replacing valve).Get Price
Normal operating pressure for Burnham gas boiler 20141114 — I have a Burnham P205W gas boiler for the baseboard radiators in a 2 story house. The water Is 20 psi a normal operating pressure for residential boilers? Two different schools of …Get Price
Bryan Steam Corporation guarantees the boiler pressure vessel against thermal shock for twenty years after date of installation, non-prorated. HED-Series forced draft firing hot water boilers are built and stamped in accordance with the requirements of the A.S.M.E. boiler code. Constructed as standard for hot water operating pressures to 60 psi.Get Price
Aug 08, 2019 · Burnham Commercial's commitment to quality and dependability continues with the Series 8H/8HE. The features and efficiency of the 8H/8HE boiler make it ideal for single and multiple boiler applications. Offering space heating, or a combination of heating and domestic hot water, the Series 8H/8HE has a compact design which easilyGet Price
Boiler PSI is at 35 how to reduce it on a Burnham 204 gas installed 2000. Ask Question Asked You will need to find out if the pressure in the boiler is actually 35psi or is the gauge out of calibration. clean, and test all the operating and safety controls and return the boiler to a safe operating condition. You are not saving money Get Price
GAS - FIRED BOILER 9700609. 2 the pressure and temperature of the boiler. This boiler contains components which become very hot when the boiler is operating. Do not touch any components unless they are cool. Boiler materials of construction, products of combustion and the fuel contain alumina, silica, heavy metals, Get Price
High Pressure steam. Combustion Gases. Chemicals. Moving Machinery. Hot Surfaces. 8-There are four major categories of catastrophic failure which exists in the boiler itself. 1. Melt down. This is a result of the heating surface metal reaching its melting point. It is a result of the boiler operating on very low water conditions.Get Price
At normal atmospheric pressure, any further addition of heat to water at boilers, package boilers Multiple gas paths - 2, 3 and 4 pass Internal furnace or fire box as the 1st pass Dry back or wet back design operating boiler ? • British Standard BS2486:1997Get Price
Dec 04, 2018 · I have a Buderus GB142 gas boiler and the water pressure is to high (P26). How do I lower it? It should be around P15. Contractor's Assistant: How long has this been going on? And how severe is the problem? It has been this way for about a month and I've been told it's severe as the max before the pressure valve releases is P30.Get Price
The boiler vessel is a two pass hybrid design incorporating a water tubed boiler-type water membrane and a two-pass fire tube scotch marine vessel. The Hybrid RG design is suitable for applications to produce high pressure steam or hot water in ranges from 3,450 - 60,000 lbs/hr (3.4 mm BTU - 60 mm BTU) output from 100 up to 900 PSI.Get Price
Aralsan Solid Fuel Fired Steam Boilers. Aralsan steam boilers which are manufactured with Aralsan's sophisticated engineering knowledge produce steam in the safetiest and the most economic way. Certified in accordance with 2014/68/EU PED and delivered with CE sign. ALL IN ONE type package steam boiler including its all necessary equipment.Get Price
GAS - FIRED BOILER 9700609. 2 determine the pressure and temperature of the boiler. This boiler contains components which become very hot when the boiler is operating. Do not touch any components unless they are cool. Boiler materials of construction, products of combustion and the fuel contain alumina, silica, heavy Get Price
Jan 23, 2019 · Most cast iron boilers are rated for up to 50 psi operating pressures, though the pressure relief valves shipped for residential boilers are usually 30 psi. Boilers that size serving taller multi-story buildings need more pressure than …Get Price
normal pressure boiler, normal pressure boiler Suppliers May 15, 2015 · Measure the gas pressure with a manometer at the port provided in the gas valve. In a multiple boiler installation, gas pressure should initially be set for a single boiler in operation and then remaining boilers should be staged on at full fire to ensure that gas Get Price
Dec 30, 2019 · In any event, the usual cold pressure of a boiler should sit at about 12psi (pounds per square inch). Most pressure gauges display different-colored zones. If the needle sits much outside the green zone, particularly on the high …Get Price
How to Set Hot Water or Steam Heating System Pressure Get Price
Aug 08, 2019 · Burnham Commercial's commitment to quality and dependability continues with the Series 8H/8HE. The features and efficiency of the 8H/8HE boiler make it ideal for single and multiple boiler applications. Offering space heating, or a combination of heating and domestic hot water, the Series 8H/8HE has a compact design which easilyGet Price
Jan 15, 2021 · The boiler doesn't have power: The circuit breaker or fuse controlling the furnace may have tripped or blown.Reset the tripped circuit breaker or replace a blown fuse.; The water level is low: Maintain the water level in the boiler at half-full.The boiler's automatic filling system, controlled by the pressure-reducing valve, should maintain the proper water level at 12 to 15 …Get Price
I have a Burnham gas fired boiler P-204-W, but do not have a manual. Is it possible to get one? Thanks. Bob N Says: November 24th, 2015 at 4:23 pm. My dad is trying to repair his Burnham gas boiler. He says the following numbers appear on the stamped plate in the unit: G …Get Price
Dec 03, 2013 · Standard residential hot water boiler max operating pressure is 30 psi. Rick : You would have to contact Burnham directly for an answer to the test pressure and documentation part of your question. Here is the contact info for the Burnham manufacturer I have a Burnham Series 2 gas boiler for a forced hot water system. There are two zones Get Price
determine the temperature and pressure of the boiler. This boiler contains components which become very hot when the boiler is operating. Do not touch any components unless they are cool. • High water temperatures increase the risk of scalding injury. If …Get Price