Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Reboilers Kettle versus Thermosiphon Designs

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Reboilers Kettle versus Thermosiphon Designs
  • Supply Capacity : 10 units/month :Reboilers Kettle versus Thermosiphon Designs
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Horizontal thermosiphon - Big Chemical Encyclopedia

    The article of Fair and Klip presents a detailed analysis of the necessary design features and equations for horizontal kettle reboilers, horizontal thermosiphon reboilers, and vertical thermosiphon reboilers. Other useful references on reboilers are 185,186,188,190,192,194,195,196,197, and 201.Get Price

  • Reboilers kettle - Big Chemical Encyclopedia

    The article of Fair and Klip presents a detailed analysis of the necessary design features and equations for horizontal kettle reboilers, horizontal thermosiphon reboilers, and vertical thermosiphon reboilers. Other useful references on reboilers are 185,186,188,190,192,194,195,196,197, and 201.Get Price

  • Reboiler - Wikipedia

    Types of reboilers. The most critical element of reboiler design is the selection of the proper type of reboiler for a specific service. Most reboilers are of the shell and tube heat exchanger type and normally steam is used as the heat source in such reboilers. However, other heat transfer fluids like hot oil or Dowtherm (TM) may be used. Fuel-fired furnaces may also be used as reboilers …Get Price

  • The Design and Layout of Vertical Thermosyphon Reboilers

    Vertical thermosyphon reboilers require care in their thermal design and layout to avoid operational problems. This Guide describes the recommended design method and gives advice on layout. 1 SCOPE Vertical Thermosyphon Reboilers (VTRs) are one of several types of reboiler that may be used on distillation columns. A review of the relative Get Price

  • Best Elevation for Thermosiphon Reboiler? - Chemical plant

    May 27, 2004 · The literature that I have read on the design of vertical thermosiphon reboilers (shell & tube vertical heat exchanger) recommends setting the top tubesheet of the reboiler at the same elevation as the liquid level in the column bottom. My question is then regarding the design of the upper piping that connects the reboiler back to the column.Get Price

  • (PDF) "Design of A Vertical Thermosyphon Reboiler

    A short summary of this paper. 17 Full PDFs related to this paper. Read Paper. "Design of A Vertical Thermosyphon Reboiler" Soni Prashant C. Dept. of Chemical Engg. And Tech., Institute of Technology, Banaras Hindu University, Varanasi- 221005. Jigisha Parikh and Deepak Jain Dept. of Chemical Engg., Sarvajanik College of Engg.Get Price

  • Thermosyphon Reboilers - an overview | ScienceDirect …

    Which Design Guidelines Should Pay Close Attention to?Get Price

  • Reboilers for distillation columns in industry

    Nov 24, 2016 · Kettle reboilers are the easiest type of reboiler design you could use for your distillation process. A kettle reboiler is designed to allow a heating fluid to pass through tubes that are covered in the liquid you want to be distilled. As the liquid heats up and boils, it is sent to the distillation column and condensed by cooling liquid.Get Price

  • (PDF) Criteria for the vapor space design in kettle reboilers

    A New Way to Design Kettle and Internal Reboilers, Hydrocarbon Processing, V. 43, No. 11, p. 199 1964. Evaporation Technology, VCH Verlagsgesellscahft mbH Jan 1989Get Price

  • Kettle Reboiler Design Presentation. | PDF | Boiling

    The kettle diameter is determined by the criterion that the actual vapor velocity is less than the maximum allowable velocity. These velocities are defined in the HTRI Design Manual. Entrainment ratios for kettle sizing are as follows: Steam generator = 0.001 liq-wt/vap-wt, Others = 0.01 liq-wt/vap-wt Page-4 Kettle Exchangers SizingGet Price

  • Kettle Type Reboiler Working - Chemical Engineering World

    May 31, 2020 · Kettle Type Reboiler Working:-A reboiler is an equipment which is installed with the distillation column and its purpose is to convert the liquid which is provided by the bottom tray of the distillation column into vapours.These vapours are then returned to the distillation column. A reboiler is essentially a heat exchanger . Kettle type reboiler is one of the most common …Get Price

  • Reboilers for distillation columns in industry

    Nov 24, 2016 · Kettle reboilers are the easiest type of reboiler design you could use for your distillation process. A kettle reboiler is designed to allow a heating fluid to pass through tubes that are covered in the liquid you want to be distilled. As the liquid heats up and boils, it is sent to the distillation column and condensed by cooling liquid.Get Price

  • Best practices for design and operation of reboilers with

    Another type of proprietary reboiler a (Fig. 3) consists of one or more BAHX blocks inside a steel vessel.The warm stream enters the left side of the vessel and cools as it passes through the heat exchanger. The cold stream enters the vessel as liquid (or partially liquid), and a liquid level is formed outside the exchanger to create a liquid head that drives the cold stream through the …Get Price

  • Solved: Compare a kettle reboiler with a thermosyphon

    Kettle reboiler. Thermosyphon. Boiling takes place on tubes immersed in a pool of liquid. All the liquid from the. bottom tray flows to the. reboiler. No circulation of liquid through the exchanger. None of the liquid from the. bottom of the tower flows. to the reboiler. Easy to design. slightly difficult. Suitable for foaming liquids and Get Price

  • Select the Right Reboiler - Chemical Processing

    Jun 04, 2012 · Select the Right Reboiler. Reboilers provide vapor for a distillation tower. The most common type of reboiler is some variant of a shell-and-tube (S&T) exchanger — because such exchangers can satisfy a wide range of process and mechanical requirements at reasonable costs. " Reboiler selection requires several critical choices.Get Price

  • Characteristicsofthermosiphonreboilers

    design of thermosiphon reboilers has to take special care for a low pressure drop. Generally, just 5 (inorganicliquids) to 20 (organicliq-uids) weight percent of the liquid is evaporated.Thus, the liquid circulates several times before complete evapora …Get Price

  • Chapter 6 REBOILERS AND VAPORISERS

    Design of Thermosyphon reboilers The design of thermosyphon reboilers is complicated by the fact that, unlike a forced convection reboiler, the fluid circulation rate cannot be determined explicitly. The circulation rate, heat-transfer rate and pressure drop are all interrelated, and iterative design procedures must be used.Get Price

  • Chapter 7: How Reboilers Work Thermosyphon, Gravity Feed

    Overview Four types of reboilers are discussed in this chapter: Once-through thermosyphon reboilers Circulating thermosyphon reboilers Forced-circulation reboilers Kettle or gravity-fed reboilers There are dozens of other types of reboilers, but these four represent the majority of applications. Learn more about Chapter 7: How Reboilers Work Thermosyphon, Gravity Feed, …Get Price

  • CHAPTER 52 HEAT EXCHANGERS, VAPORIZERS, CONDENSERS

    This type is used exclusively for kettle reboilers and vaporizers, and is characterized by the oversized shell intended to separate vapor and liquid phases, Fig. 52.8. Shell-sizing relationships are given in Ref. 25. Usually, the shell diameter is about …Get Price

  • "Managing Reboiler Steam-side Operation - Martech Systems

    boiler designs are kettle, forced recircu-lation and thermosiphon. Kettle Reboilers Kettle reboilers, also known as pool boilers, are often used for light hydro-carbons (propane, butane). These re-boilers handle process flow fluctuations and high heat fluxes better than other reboiler designs, but kettle reboilersGet Price

  • Solved: Compare a kettle reboiler with a thermosyphon

    Kettle reboiler. Thermosyphon. Boiling takes place on tubes immersed in a pool of liquid. All the liquid from the. bottom tray flows to the. reboiler. No circulation of liquid through the exchanger. None of the liquid from the. bottom of the tower flows. to the reboiler. Easy to design. slightly difficult. Suitable for foaming liquids and Get Price

  • PreFEED Distillation Separation Effect by Thermosiphon

    Solutions for R&D to Design 8 Thermosiphon versus Kettle -2 Overhead MeOH Concentration Thermosiphon: 0.750 Kettle: 0.745 In the case where one theoretical stage is added to model B (model C), the thermosiphon has better separation. 3. Kettle Type Model: Number of theoretical stages =7 + (internal condenser + kettle reboiler) FEED TH-OVHD TH Get Price

  • Kettle reboiler design - heat exchanger software - thermal

    Feb 08, 2022 · Kettle Reboiler design, This software tool is made to demonstrate the thermal design calculations and analysis of Kettle type reboilers. The software is user friendly and can be used to make preliminary sizing calculations that will help to give a clear outlook of the initial. Kettle Reboiler design (KRD) Software FeaturesGet Price

  • Chapter 6 REBOILERS AND VAPORISERS

    Design of Thermosyphon reboilers The design of thermosyphon reboilers is complicated by the fact that, unlike a forced convection reboiler, the fluid circulation rate cannot be determined explicitly. The circulation rate, heat-transfer rate and pressure drop are all interrelated, and iterative design procedures must be used.Get Price

  • Reboilers Short Course | HTRI

    This course provides an overview of selected reboiler configurations with an emphasis on recirculating thermosiphon reboilers and kettles. We will develop accurate thermosiphon and kettle models using X ist, identify design guidelines based on current research, and discuss reboiler piping specifications in X ist .Get Price

  • 054410 Plant Design - University of Maryland, Baltimore County

    Horizontal Reboilers: 8 - 16 PLANT DESIGN - Daniel R. Lewin Reboiler Circuit Design Circulating Reboiler Design Horizontal Reboilers: 23 1 12 288 p H H ρ ρρ ∆+ ≥ − ∆≤∆=∆ +∆ +∆Pp p p p d er ∆= −PHH(1288)(ρ 11 2 2ρ) Note that draw-off is from the bottom here! Here H 2 = H 1 + H 3. Thus, the minimum down-comer nozzle Get Price

  • Bottoms Reboiler - EnggCyclopedia

    This reboiler, which is essentially a heat exchanger, heats up the liquid.A reboiler may use steam, fire, another hot liquid etc. to provide heat and depending on the heating medium used there are different types of reboilers namely - kettle type, fired, thermosiphon reboilers etc.Get Price

  • Advantages and Disadvantages of Reboilers - Bizfluent

    Sep 26, 2017 · Kettle reboilers are reliable in that they can handle high vaporization of up to 80 percent and are easy to maintain. The liquid from the bottom of the tower flows through the tube bundle and exits as condensate. A restraining device (baffle) controls the liquid level over the bundle. However, the high level of vaporization makes it prone to Get Price

  • Thermosyphon Reboiler - Chemical Engineering World

    Jun 02, 2020 · Thermosyphon Reboiler:-A reboiler is an equipment which is installed with the distillation column and its purpose is to convert the liquid which is provided by the bottom tray of the distillation column into vapours. These vapours are then returned to the distillation column. A reboiler is essentially a heat exchanger.Get Price

  • Thermal Design Of Reboilers - Heat Exchangers - Brewiki

    Reboilers: Kettle versus Thermosiphon Designs "I would like some guidance on the relative benefits of kettle vs. vertical thermosiphon reboilers in NGL (DeC3 and DeC4) service. Specifically we are looking at a turndown of 4:1 and some are concerned that …Get Price

Discount
7X24 Online