Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Steam Boiler Header Piping Outlets for Mechanical

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Steam Boiler Header Piping Outlets for Mechanical
  • Supply Capacity : 10 units/month :Steam Boiler Header Piping Outlets for Mechanical
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Section 23 21 11 - BOILER PLANT PIPING SYSTEMS

    The header shall be the connection point for steam piping from all boilers and for steam distribution piping. ASTM A105/A105M Grade 2, may be applied in lieu of tees for all branch outlets less than the full size of the header. Comply with fitting manufacturer's recommendations and requirements of ASME B31.1 and MSS SP-97 Get Price

  • The Interactions Between Steam Piping and Boiler Outlet

    between main steam and hot/cold reheat steam piping and their associated boiler outlet/inlet headers, but the same interface problems can apply to feedwater piping and the economizer inlet header. The case studies will focus on the actual cause and effect scenarios on boiler and steam piping components due to malfunctioning supports.Get Price

  • How NOT to Design a Steam System - The C&S Companies

    The Basics: What Pressure Should my Boiler Be?Get Price

  • Electric Steam Boiler Manual - Vapor Power

    2.0 MECHANICAL INSTALLATION 2.1 STEAM SUPPLY Install a steam stop valve on the steam outlet of the boiler and pipe to the equipment to be supplied with steam. NOTE: IF THE BOILER IS TO BE CONNECTED TO A COMMON HEADER WITH ONE OR MORE OTHER BOILERS, TWO STOP VALVES ARE REQUIRED BY CODE,Get Price

  • US20110079217A1 - Piping, header, and tubing arrangements

    A header system for fluid circulation in a boiler includes a header configured to conduct fluid therethrough for circulating fluids in a boiler. A plurality of suction lines are connected in fluid communication with the header. Each suction line is configured and adapted to connect a respective pump in fluid communication with the header.Get Price

  • STEAM SYSTEM DESIGN AND COMMISSIONING GUIDANCE - …

    _____ Ensure steam boiler outlets are piped to the main steam header. _____ Ensure all valves and sensors are installed in the steam piping. _____ Ensure there is a means to dump steam for boiler testing and over pressure protection. 6. Condensate system installation _____ Ensure all steam using equipment is trapped.Get Price

  • Steam System Components - Boiler, Steam Header | CSI Heat

    Steam Header Steam exits the boiler through piping referred to as the steam header. The header also serves as a reservoir that feeds steam to the individual heating circuits. The steam header must be large enough to virtually eliminate pressure …Get Price

  • Pre-Inspection Checklist for Low Pressure Steam Boilers

    steam boiler and a stop valve or cock between the check valve and the steam boiler or between the check valve and the piping system. Section IV HG-710 In lieu of a check valve in the feedwater line, a back flow preventive device may be used if the device's minimum pressure rating is equal to the pressure stamped upon the steam boiler, andGet Price

  • Steam System Components - Boiler, Steam Header | CSI Heat

    The best boilers to keep you warm in 2021 - Confused.comGet Price

  • The importance of near-boiler piping in a steam system

    Jun 24, 2014 · In a real boiler room, that piping would be steel and threaded so the header can move against those elbows as it expands and contracts. This keeps stress off of the boiler sections. It's the reason why copper is a bad idea when it comes to steam piping. The twisting can break a soldered fitting. But about those two risers.Get Price

  • Two-Pipe HVAC Makes a Comeback: An Idea Discarded …

    A 2-pipe HVAC system is one that uses the same piping alternately for hot water bypasses the chiller and goes to a header that feeds the boilers. When the chiller. The "heat trap" where the boiler and chiller outlets converge, is an example of the design ingenuity. ASHRAE handbooks show anywhere from two to six motorizedGet Price

  • Mechanical Engineering STREAM BOILERS Terms and

    Mechanical Engineering STREAM BOILERS Terms and Definitions :-. AIR PREHEATER – A device that makes the final heat recovery from boiler flue gases and uses the same to preheat the incoming furnace air for its reaction with fuel. ANTI-INCRUSTATOR – A substance used to prevent the formation of scale on the internal surfaces of steam boilers.Get Price

  • Steam Boiler Header Piping Outlets for Mechanical …

    Victaulic steam boiler header piping outlets can be used as a header for any mechanical room application. The steam outlet headers are available with Original Groove System (OGS) ends or Advanced Groove System ends.Get Price

  • Boiler Service & Repair | The Energy Co. Incorporated

    The Energy Company is a full service mechanical contractor in the boiler industry offering service, repair and maintenance of all types of boilers and boiler installations including water tube, fire tube and cast iron boilers. Our professional repair crews have extensive experience with a wide range of boilers, burner controls and installations Get Price

  • Hydraulic separator piping to indirect water heater, boilers

    Feb 11, 2016 · He selects a hydraulic separator for the project, and connects the piping of the indirect water heater on the same side as the boilers. He also specifies a motorized valve, as shown in the schematic. This valve will close during the domestic water heating cycle so that one or both of the boiler circulators can only drive flow through the Get Price

  • POWER BOILERS ASME SECT. I & POWER PIPING …

    Tips for a Successful Steam Boiler Replacement | U.S. Boiler Get Price

  • A Steam Heating Primer

    Jun 25, 2014 · Allow at least 24 inches between the top of the boiler and the bottom of the steam header. Use full-size risers to the header. Pipe the system take-offs at a point between the last riser to the header and the equalizer. Pipe the swing joints into the header. Use a reducing elbow to connect the header to the equalizer.Get Price

  • NEAR STEAM BOILER PIPING — Heating Help: The Wall

    What Should The Boiler Pressure Be When The Heating Is On? |Get Price

  • TYPICAL PIPING FOR CONVENTIONAL SINGLE BOILER …

    • PIPE RELIEF VALVE TO OPEN DRAIN Model LB Recommended Flow Rate @ 20°(F)Temp. Rise Boiler Inlet & Outlet Flow (inches) (gpm) Head Loss (feet) 5400 469". 2 7650 601"0. 2 18000 868". 2 System Notes: • The System Pump must be sized to maintain the minimum recommended flow rate through the boilers. The pump must operate continuous or cycle Get Price

  • A Steam Heating Primer - HVAC School

    Feb 02, 2019 · Allow at least 24 inches between the top of the boiler and the bottom of the steam header. Use full-size risers to the header. Pipe the system take-offs at a point between the last riser to the header and the equalizer. Pipe the swing joints into the header. Use a reducing elbow to connect the header to the equalizer.Get Price

  • NEAR STEAM BOILER PIPING — Heating Help: The Wall

    Hi all, Pls I need second opinion regarding near boiler piping of a steam boiler. We are about to install 2 new steam boilers. 2 Old steam boilers were 2'' diameter coming out from the boiler to a 4'' common header and to another 5'' riser to the attic which circle round the attic area then feed down to radiators.Get Price

  • The flow of fluids in boilers and steam generators | P.I

    Nov 11, 2019 · All boiler headers, piping and tubes are usually made of seamless steel alloy piping or tubes (from suitable alloy steels). Consideration is needed for the material of tubes/piping, arrangement of tubes/pipes and flow velocities in the tubes/pipes, as well as provisions to prevent high-temperature steam corrosion and steam oxidation of tubes.Get Price

  • Industrial Boiler Steam Header

    An introduction to steam generation and distribution. 17 Types of industrial steam boilers 17 Coil steam generator (once through boiler) 19 Water-tube boiler 21 MTHS boilers (fire-tube or smoke-tube boilers) 24 Basic overview of boiler controls with reference to EN 12953 25 Water treatment 28 Level controls 29 Feedwater pump arrangements 30 Burners 33 Basic steam distribution 37 …Get Price

  • Installation Instructions Low-Loss Header - Viessmann

    Low-loss header Flange of low-loss header, ANSI standard Drain connection, 2" NPT male Low-loss header label *Immersion or strap-on sensor depending on application and boiler/control models. Note: All counter flanges shall be ANSI standard (field supplied). 1.Before commencing with the installation, plan the location and orientation of the Get Price

  • Basement pipe insulation for Steam Boiler — Heating Help

    There s nothing wrong w a 2 inch equilizer . That boiler should have both 2 inch tapping rising a mimiun of 24 inch theres should be a tee installed directly on the outlet before the vertical pipe in installed,both of those riser should go into a 3 inch header,they should be tied together using a swing joint your existing srteam mains should tie in after your boiler risers after which it Get Price

  • Failure Analysis Study of a Cracked Superheater Outlet Header

    boiler header and steam piping components. Background During a forced outage of the Unit 1 boiler in September of 1992, extensive internal bore-hole and ligament cracking was discovered in the radiant superheater outlet header. Based on the results of a comprehensive engineering evaluation of the cracked header, the unit was returnedGet Price

  • Volume 1, Steam Boilers - Steam, Heating Hot Water, and

    1.4.2 When replacing an existing boiler, header pressures shall not be changed (raised or lowered) from the existing unless a complete engineering analysis is performed on affected portions of the steam system of the facility to determine the effect of higher/lower pressures and temperatures on pipe expansion devices, steam traps,Get Price

  • Top 10 facts about the Harford Loop - Plumbing & Mechanical

    Jul 29, 2014 · 1. A Hartford Loop is an arrangement of piping between a steam boiler's header and its gravity-return piping. The end of the header drops vertically below the boiler's water line and connects into the bottom of the boiler. We call this pipe the "equalizer" because it balances the pressure between the boiler's steam outlet and Get Price

  • Boiler Basics Part 4 - Piping - HVAC School

    Jan 28, 2017 · However, the piping pitch is much more crucial to this system. The piping must have pitch or fall to help the steam rise, and more importantly, to allow the condensate to flow back to the boiler. Level piping holds water, so it must have fallen. Also, a Hartford Loop is required to connect the supply and return.Get Price

  • 5th Period Final (packets) Flashcards | Quizlet

    Near boiler piping in a two-pipe mechanical condensate return system should have a steam header installed at a minimum of __" above the NOWL of the boiler 24 When the return main is above the coil, a pressure differential of 1 psig for each ___' of elevation must be availed at the steam trap discharge to ensure continuous condensate removal Get Price

Discount
7X24 Online